Skip to main content Skip to search Skip to main navigation

ORA™ UDG Multiplex qPCR Probe ROX L Mix, 4X – multiplex qPCR with UDG

ORA™ UDG Multiplex qPCR Probe ROX L Mix, 4X – multiplex qPCR with UDG

Applications

  • qPCR assays based on specific probes: including TaqMan®, Molecular Beacons, Scorpions™ Probes
  • Multiplex quantification of several targets from minimal template amounts
  • Quantification of gDNA, cDNA, viral DNA, low copy number genes, gene expression analysis

Benefits

  • Highly concentrated master mix with UDG and dUTP for use with maximum template volume, and multiple primers and probes
  • Prevents PCR carryover contamination
  • Great for multiplexing, excellent performance on GC-rich templates
  • Universal – standard and fast cycling, GC- or AT-rich templates
  • Rapid extension, early Ct
  • Supplied with PCR Water

ORA™ UDG Multiplex qPCR Probe ROX L Mix, 4X

Product information "ORA™ UDG Multiplex qPCR Probe ROX L Mix, 4X"

The 4X concentrated ORA™ UDG Multiplex qPCR Probe ROX L Mix is an excellent solution for demanding qPCR assays that require the quantification of multiple targets from minimal template amounts. The mix can be used with all probe types and with a wide range of sample amounts, from very low-copy-number targets in diluted samples to abundant templates.

The mix contains all components required for a robust qPCR; only template, primers and probes need to be added. Its high concentration enables the use of maximal template volume as well as multiple primers and probes. The UDG version includes dUTP and UDG (uracil-DNA glycosylase), which degrades dUTP-containing contaminating DNA and prevents PCR carryover contamination. highQu qPCR master mixes are based on a small-molecule inhibitor Hot Start technology, which provides the highest sensitivity and specificity under both standard and fast cycling conditions. Mix is supplied with PCR Water.

Proven 3-plex performance: 3-plex reactions (FAM, HEX, Texas Red) on a cDNA dilution series from 100000 to 100 copies show comparable performance with and without UNG treatment.

The ORA™ UDG Multiplex qPCR Probe ROX L Mix contains ROX at low concentration; the version without ROX is available as ORA™ UDG Multiplex qPCR Probe Mix, 4X. If a high ROX concentration or more ROX flexibility is required, ROX for qPCR Mixes, 50 µM can be obtained separately and added directly to the qPCR mix. For multiplexing with the ROX channel kept free for a probe dye, see the ORA™ Multiplex qPCR Probe Mix MP, 4X.

Large pack sizes are available – contact us at info@highQu.com for bulk and custom formats.

You may also need: ORA™ qPCR Probe ROX L Mix for standard singleplex probe qPCR and 4X 1Step Multiplex RT qPCR Probe Mix MP for multiplex one-step RT-qPCR.

Skip product gallery

Related Products

ORA™ qPCR Probe ROX L Mix
ORA™ qPCR Probe ROX L Mix

highQu qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization. Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Master mixes are available in three versions – without ROX, with low or high ROX concentration.

Variants from €129.50
Regular price: €117.50
ORA™ SEE qPCR Probe ROX H Mix
ORA™ SEE qPCR Probe ROX H Mix

highQu qPCR master mixes are based on the small molecular inhibitor technology Hot Start PCR allowing to achieve highest sensitivity and specificity under both standard and fast qPCR cycling conditions. They provide excellent results on both AT and GC rich templates, in multiplexing and guaranty rapid extension with early Ct values with minimum or no optimization. ORA™ SEE qPCR mixes provide an additional advantage of a simplified tracking of the process, as they are colored with an inert blue dye to make samples much better visible during pipetting and handling. Our master mixes are supplied with PCR Water to guaranty the best performance. To suit the broad instrument range the ORA™ qPCR Probe Master mixes are available in three versions – without ROX, with low or high ROX concentration.

Variants from €129.50
Regular price: €117.50
ALLin™ Hot Start Taq Mastermix
ALLin™ Hot Start Taq Mastermix

highQu ALLin™ Hot Start Taq DNA Polymerase is the superior sensitive enzyme The activity at room temperature is blocked by small molecular inhibitor. Enzyme becomes active only after heating what allows for highly specific and extremely sensitive amplification, no primer dimer formation and no background. In combination with the optimized ALLin™ buffer enzyme provides higher success rates in demanding PCR applications like amplification of complex or longer templates and fast cycling. ALLin™ Hot Start Taq DNA Polymerase has the same PCR accuracy like Taq DNA Polymerase, 4.5 x 10^4 (nucleotides incorporated before the error occurs) and produces A-tailed products suitable for ligating into TA cloning vectors. The convenience of ALLin™ Hot Start Taq DNA Polymerase is maximized by the use of 2X Mastermix providing the additional advantage of reduced pipetting and minimized errors. The mastermix is even supplied with PCR Water, and the only thing to add is the template with primers.

Variants from €208.50
Regular price: €189.50
ALLin™ Mega HiFi DNA Polymerase
ALLin™ Mega HiFi DNA Polymerase

Derived from our HiFi polymerase, the highQu ALLin™ Mega HiFi DNA Polymerase provides much lower error rate PCR with a 100 higher fidelity compared to Taq. The ALLin™ Mega HiFi DNA Polymerase is engineered to be much faster and to generate a higher yield of long PCR products up to 20 kb from complex GC-rich templates. Therefore the ALLin™ Mega HiFi DNA Polymerase is an excellent choice for longer and very complex PCR applications where the highest fidelity is demanded. It is an enzyme of choice for cloning and all kind of sequencing applications including NGS. Generated blunt-ended PCR products are suitable for ligation into blunt vectors. For maximum convenience, the ALLin™ Mega HiFi Mastermix, 2X (HLM0201) and ALLin™ Mega HiFi Red Mastermix, 2X (HLM0301) are available. Pfu DNA Polymerase was originally found in thermophilic bacterium Pyrococcus furiosus. It is a thermostable DNA polymerase that was widely used in molecular biology applications for its high fidelity of DNA amplification due to a high proofreading activity. Pfu polymerase has 3' to 5' exonuclease proofreading activity, which enables it to correct errors that occur during DNA synthesis. The enzyme is commonly used for cloning and sequencing applications, however it is relatively slow, sensitive to contaminants and inhibitors and has low processivity resulting in usually low PCR yields. Alternative, mostly better DNA polymerases have been developed by different companies to address the limitations of Pfu polymerase. These include such enzymes as Phusion® DNA polymerase, Q5® DNA polymerase from NEB, and many others. These enzymes offer improved elongation rates, reduced error rates, and increased efficiency for NGS applications. The ALLin™ MEGA HiFi Polymerase offered by highQu provides 100X higher fidelity compared to Taq Polymerase, which is much higher than Pfu. In addition, the hot start enzyme version allows to reduce the background to the minimum. Such robust enzyme offers not only precise amplification, but also enables PCR from very complex templates and generation of very long PCR products up to 30 kb and above. Availability of faster, more robust and more precise polymerases influenced successful development of next generation sequencing techniques (NGS) where PCR precision and yield is crucial for reliable sequencing results.

Variants from €109.50
Regular price: €99.50