Skip to main content Skip to search Skip to main navigation

One-Step RT Probe qPCR

Want to use the highest volume of the sample? Use new 4X 1Step RT qPCR Kits!

Selection guide: 1Step RT qPCR Probe Kits & Mixes

 No ROXROX LMultiplex MPHigh ROX
qPCR Instrument
(Company, ROX requirement)
2X 1Step RT qPCR Probe Kit4X 1Step RT qPCR Probe Kit2X 1Step RT qPCR Probe ROX L Kit4X 1Step RT qPCR Probe ROX L Kit4X 1Step Multiplex RT qPCR Probe Mix MPROX for qPCR Mixes (separate ROX)
iCycler iQ® / MyiQ™ / iQ™5
(Bio-Rad, No ROX, Fluorescein)
●●
CFX Connect™
(Bio-Rad, No ROX)
●●●●
CFX Duet
(Bio-Rad, No ROX)
●●●●
CFX Opus 96 / 384
(Bio-Rad, No ROX)
●●●●
CFX96™ / CFX384™ (Touch)
(Bio-Rad, No ROX)
●●●●
Chromo4™ / Opticon™ / Opticon™ 2 / MiniOpticon™
(Bio-Rad, No ROX)
●●●●
Cielo™ 3 / 6
(Azure Biosystems, No ROX)
●●●●
Eco™
(Illumina / PCRmax, No ROX)
●●●●
FluoroCycler® 96
(Hain Lifescience, No ROX)
●●●●
LightCycler® 96 / 480 / 480 II / PRO / Nano
(Roche, No ROX)
●●●●
LineGene 9600 Plus
(Bioer, No ROX)
●●●●
Mastercycler® ep realplex / realplex 2S
(Eppendorf, No ROX)
●●●●
Mic
(Bio Molecular Systems, No ROX)
●●●●
MyGo Pro / MyGo Mini
(IT-IS Life Science, No ROX)
●●●●
PikoReal™
(Thermo Scientific, No ROX)
●●●●
PrimeQ / Quantica®
(Techne, No ROX)
●●●●
QIAquant® 96 / 384
(QIAGEN, No ROX)
●●●●
qTOWER³ / qTOWER 2.0 / qTOWER / qTOWERiris
(Analytik Jena, No ROX)
●●●●
Rotor-Gene® Q / 6000 / 3000
(QIAGEN, No ROX)
●●●●
SmartCycler®
(Cepheid, No ROX)
●●●●
Thermal Cycler Dice™ Real Time
(Takara Bio, No ROX)
●●●●
TOptical
(Biometra (Analytik Jena), No ROX)
●●●●
Xxpress®
(BJS Biotechnologies, No ROX)
●●●●
AriaMx / AriaDx
(Agilent, ROX optional, low 30 nM)
●●●●
ViiA™ 7
(Applied Biosystems, Low ROX 30–50 nM)
●●●
7500 / 7500 Fast
(Applied Biosystems, Low ROX 30–50 nM)
●●●
QuantStudio™ 5
(Applied Biosystems, Low ROX 30–50 nM)
●●●
QuantStudio™ 6 / 7 Flex, 12K Flex
(Applied Biosystems, Low ROX 30–50 nM)
●●●
QuantStudio™ 6 / 7 Pro
(Applied Biosystems, Low ROX 30–50 nM)
●●●
Mx3000P® / Mx3005P® / Mx4000P®
(Agilent (Stratagene), Low ROX 30–50 nM)
●●
QuantStudio™ 1
(Applied Biosystems, Low ROX 30–50 nM)
●●
QuantStudio™ 3
(Applied Biosystems, Low ROX 30–50 nM)
●●
7000
(Applied Biosystems, High ROX 500 nM)
●
7300
(Applied Biosystems, High ROX 500 nM)
●
7700
(Applied Biosystems, High ROX 500 nM)
●
7900 / 7900HT / 7900HT Fast
(Applied Biosystems, High ROX 500 nM)
●
StepOne™ / StepOnePlus™
(Applied Biosystems, High ROX 500 nM)
●
BioMark™
(Fluidigm (Standard BioTools), High ROX 500 nM)
●

Instruments marked “No ROX” do not need a passive reference; the low ROX of ROX L mixes does not interfere.

High-ROX instruments: add ROX for qPCR Mixes (ROX0105, 50 µM) separately to the mix.

MP mixes contain a red passive reference dye (Cy5 channel) instead of ROX, keeping the ROX channel free for probe dyes. On 7500 and 7500 Fast systems, a calibration for the red passive reference dye is required.

 

One-step RT-qPCR probe kits for RNA and virus detection

One-step RT-qPCR combines reverse transcription and qPCR in a single tube. Fewer pipetting steps mean faster setup, less risk of contamination and more reproducible results – ideal for viral RNA detection, pathogen testing and gene expression analysis. highQu one-step RT-qPCR probe kits combine a robust hot-start qPCR mix with a thermostable reverse transcriptase blend and work with TaqMan® probes, Molecular Beacons and Scorpions™ probes.

2X kits for standard one-step RT-qPCR

The 2X 1Step RT qPCR Probe Kit (no ROX) and the 2X 1Step RT qPCR Probe ROX L Kit (low ROX) contain a 2X qPCR mix and a separate RT enzyme blend, so you can adjust the reverse transcription conditions to your assay.

4X kits for maximum sample volume

The 4X 1Step RT qPCR Probe Kit and the 4X 1Step RT qPCR Probe ROX L Kit combine a 4X qPCR mix with a 20X RT blend. The high concentration leaves room for more template – ideal for sensitive detection of viral RNA in diluted, high-volume samples.

Multiplex one-step RT-qPCR

The 4X 1Step Multiplex RT qPCR Probe Mix MP contains reverse transcriptase, RNase inhibitor and hot-start Taq DNA polymerase in a single 4X tube. Its red passive reference dye is detected in the Cy5 channel, keeping the ROX channel free for an additional probe dye – for multiplex reactions up to 10-plex and beyond on QuantStudio™, ViiA™ 7 and 7500 systems.

Related products

Need larger pack sizes, bulk volumes or custom formulations? Contact us at info@highQu.com.

Professionally Simple