Skip to main content Skip to search Skip to main navigation

One-Step RT Dye qPCR

Include universal qPCR mixes, for both standard and fast cyclers

Selection guide: 1Step RT qPCR Green Kit

qPCR Instrument
(Company, ROX requirement)
1Step RT qPCR Green ROX L KitROX for qPCR Mixes (separate ROX)
iCycler iQ® / MyiQ™ / iQ™5
(Bio-Rad, No ROX, Fluorescein)
●
CFX Connect™
(Bio-Rad, No ROX)
●
CFX Duet
(Bio-Rad, No ROX)
●
CFX Opus 96 / 384
(Bio-Rad, No ROX)
●
CFX96™ / CFX384™ (Touch)
(Bio-Rad, No ROX)
●
Chromo4™ / Opticon™ / Opticon™ 2 / MiniOpticon™
(Bio-Rad, No ROX)
●
Cielo™ 3 / 6
(Azure Biosystems, No ROX)
●
Eco™
(Illumina / PCRmax, No ROX)
●
FluoroCycler® 96
(Hain Lifescience, No ROX)
●
LightCycler® 96 / 480 / 480 II / PRO / Nano
(Roche, No ROX)
●
LineGene 9600 Plus
(Bioer, No ROX)
●
Mastercycler® ep realplex / realplex 2S
(Eppendorf, No ROX)
●
Mic
(Bio Molecular Systems, No ROX)
●
MyGo Pro / MyGo Mini
(IT-IS Life Science, No ROX)
●
PikoReal™
(Thermo Scientific, No ROX)
●
PrimeQ / Quantica®
(Techne, No ROX)
●
QIAquant® 96 / 384
(QIAGEN, No ROX)
●
qTOWER³ / qTOWER 2.0 / qTOWER / qTOWERiris
(Analytik Jena, No ROX)
●
Rotor-Gene® Q / 6000 / 3000
(QIAGEN, No ROX)
●
SmartCycler®
(Cepheid, No ROX)
●
Thermal Cycler Dice™ Real Time
(Takara Bio, No ROX)
●
TOptical
(Biometra (Analytik Jena), No ROX)
●
Xxpress®
(BJS Biotechnologies, No ROX)
●
AriaMx / AriaDx
(Agilent, ROX optional, low 30 nM)
●
ViiA™ 7
(Applied Biosystems, Low ROX 30–50 nM)
●
7500 / 7500 Fast
(Applied Biosystems, Low ROX 30–50 nM)
●
Mx3000P® / Mx3005P® / Mx4000P®
(Agilent (Stratagene), Low ROX 30–50 nM)
●
QuantStudio™ 1
(Applied Biosystems, Low ROX 30–50 nM)
●
QuantStudio™ 3 / 5
(Applied Biosystems, Low ROX 30–50 nM)
●
QuantStudio™ 6 / 7 Flex, 12K Flex
(Applied Biosystems, Low ROX 30–50 nM)
●
QuantStudio™ 6 / 7 Pro
(Applied Biosystems, Low ROX 30–50 nM)
●
7000
(Applied Biosystems, High ROX 500 nM)
●●
7300
(Applied Biosystems, High ROX 500 nM)
●●
7700
(Applied Biosystems, High ROX 500 nM)
●●
7900 / 7900HT / 7900HT Fast
(Applied Biosystems, High ROX 500 nM)
●●
StepOne™ / StepOnePlus™
(Applied Biosystems, High ROX 500 nM)
●●
BioMark™
(Fluidigm (Standard BioTools), High ROX 500 nM)
●●

Instruments marked “No ROX” do not need a passive reference; the low ROX of ROX L mixes does not interfere.

High-ROX instruments: add ROX for qPCR Mixes (ROX0105, 50 µM) separately to the mix.

 

One-step RT-qPCR with green dye detection for fast RNA quantification

Dye-based one-step RT-qPCR is a fast and economical way to quantify RNA, to analyze gene expression and to screen primer pairs without designing probes. Reverse transcription and qPCR run in a single tube, which saves time and reduces the risk of contamination. A melting curve at the end of the run confirms the specificity of the amplified product.

1Step RT qPCR Green ROX L Kit

The 1Step RT qPCR Green ROX L Kit combines a 2X qPCR mix with a green intercalating dye and a 20X reverse transcriptase blend. With its low ROX concentration, it works on all instruments that need no ROX or low ROX, including Bio-Rad CFX, Roche LightCycler®, QIAGEN Rotor-Gene®, QuantStudio™, ViiA™ 7 and 7500 systems. For high-ROX instruments, add ROX for qPCR Mixes, 50 µM separately.

Related products

Need larger pack sizes, bulk volumes or custom formulations? Contact us at info@highQu.com.

Professionally Simple