One-Step RT Probe qPCR
Want to use the highest volume of the sample? Use new 4X 1Step RT qPCR Kits!
Selection guide: which 1Step RT qPCR Probe Kit or Mix fits your qPCR instrument?
Select the 1Step RT qPCR Probe Kit or Mix according to the ROX requirement of your instrument. The multiplex mix is listed for multiplex one-step RT-qPCR.
| qPCR Instrument | Company | ROX requirement | highQu Kit / Mix to use |
| iCycler iQ® / MyiQ™ / iQ™5 | Bio-Rad | No ROX (Fluorescein) | |
| CFX Connect™ | Bio-Rad | No ROX | |
| CFX Duet | Bio-Rad | No ROX | |
| CFX Opus 96 / 384 | Bio-Rad | No ROX | |
| CFX96™ / CFX384™ (Touch) | Bio-Rad | No ROX | |
| Chromo4™ / Opticon™ / Opticon™ 2 / MiniOpticon™ | Bio-Rad | No ROX | |
| Cielo™ 3 / 6 | Azure Biosystems | No ROX | |
| Eco™ | Illumina / PCRmax | No ROX | |
| FluoroCycler® 96 | Hain Lifescience | No ROX | |
| LightCycler® 96 / 480 / 480 II / PRO / Nano | Roche | No ROX | |
| LineGene 9600 Plus | Bioer | No ROX | |
| Mastercycler® ep realplex / realplex 2S | Eppendorf | No ROX | |
| Mic | Bio Molecular Systems | No ROX | |
| MyGo Pro / MyGo Mini | IT-IS Life Science | No ROX | |
| PikoReal™ | Thermo Scientific | No ROX | |
| PrimeQ / Quantica® | Techne | No ROX | |
| QIAquant® 96 / 384 | QIAGEN | No ROX | |
| qTOWER³ / qTOWER 2.0 / qTOWER / qTOWERiris | Analytik Jena | No ROX | |
| Rotor-Gene® Q / 6000 / 3000 | QIAGEN | No ROX | |
| SmartCycler® | Cepheid | No ROX | |
| Thermal Cycler Dice™ Real Time | Takara Bio | No ROX | |
| TOptical | Biometra (Analytik Jena) | No ROX | |
| Xxpress® | BJS Biotechnologies | No ROX | |
| AriaMx / AriaDx | Agilent | Optional – low (30 nM) | |
| ViiA™ 7 | Applied Biosystems | Low ROX (30–50 nM) | 2X 1Step RT qPCR Probe ROX L Kit |
| 7500 / 7500 Fast | Applied Biosystems | Low ROX (30–50 nM) | |
| QuantStudio™ 5 | Applied Biosystems | Low ROX (30–50 nM) | |
| QuantStudio™ 6 / 7 Flex, 12K Flex | Applied Biosystems | Low ROX (30–50 nM) | |
| QuantStudio™ 6 / 7 Pro | Applied Biosystems | Low ROX (30–50 nM) | |
| Mx3000P® / Mx3005P® / Mx4000P® | Agilent (Stratagene) | Low ROX (30–50 nM) | |
| QuantStudio™ 1 | Applied Biosystems | Low ROX (30–50 nM) | |
| QuantStudio™ 3 | Applied Biosystems | Low ROX (30–50 nM) | |
| 7000 | Applied Biosystems | High ROX (500 nM) | Add extra ROX for qPCR Mixes (ROX0105, 50 µM) |
| 7300 | Applied Biosystems | High ROX (500 nM) | |
| 7700 | Applied Biosystems | High ROX (500 nM) | |
| 7900 / 7900HT / 7900HT Fast | Applied Biosystems | High ROX (500 nM) | |
| StepOne™ / StepOnePlus™ | Applied Biosystems | High ROX (500 nM) | |
| BioMark™ | Fluidigm (Standard BioTools) | High ROX (500 nM) |
NOTE: Instruments marked “No ROX” do not need a passive reference; the low ROX of ROX L mixes does not interfere.
MP mixes contain a red passive reference dye (Cy5 channel) instead of ROX, keeping the ROX channel free for probe dyes. On 7500 and 7500 Fast systems, a calibration for the red passive reference dye is required.
| Instruments See: highQu qPCR Mixes on qTOWERiris (Analytik Jena) |
2X 1Step RT qPCR Probe Kit | 2X 1Step RT qPCR Probe ROX L Kit | 2X 1Step RT qPCR Probe ROX H Kit |
| Agilent: Mx3000P®, Mx3005P®, Mx4000P® | ● | ||
| Analytik Jena: qTOWERiris, qTOWER, qTOWER 2.0, qTOWER³ | ● | ● | |
| BioRad: Opticon®, Opticon®2, Chromo4™, MiniOpticon™, CFX96™, CFX384™ | ● | ● | |
| BioRad: iCycler®, MyiQ™, iQ™5 | ● | ||
| BJS: Xxpress® | ● | ● | |
| Cepheid: SmartCycler® | ● | ● | |
| Illumina: Eco | ● | ● | |
| Eppendorf: Mastercycler® ep realplex, Mastercycler® realplex 2S | ● | ● | |
| Fluidigm: BioMark™ | ● | ||
| Hain Lifescience: FluoroCycler®96 | ● | ● | |
| Life Technologies: 7500, 7500 FAST, Viia™7, QuantStudio™ 12K Flex | ● | ||
| Life Technologies: 7000, 7300, 7700, 7900, 7900HT, 7900HT FAST, StepOne™, StepOnePlus™ | ● | ||
| QIAGEN: Rotor-Gene®Q, Rotor-Gene® 6000, Rotor-Gene® 3000 | ● | ● | |
| Roche Applied Science: LightCycler®480, LightCycler®96, LightCycler®Nano | ● | ● | |
| Takara: Thermal Cycler Dice® | ● | ● | |
| Thermo Fisher Scientific: Piko Real® | ● | ● | |
| Techne: PrimeQ, Quantica® | ● | ● |